25
NOTE: Enabling the remote set allows the remote terminal to
read and write the meter setting via Modbus-RTU,
otherwise the setting data can only be read. Default
value is ON.
6.11. REMOTE SET
a. Scroll until ”rMt SEt“ is displayed using the UP or the
DOWN button.
b. Press the NEXT button. The “PROG” symbol will blink.
Use the UP or DOWN button to toggle Enable “ON” or
disable “OFF” symbols.
c. Press the NEXT button to confi rm new setting.
d. To proceed next setting press DOWN button. To exit
programming mode, press the PROG button. The user
will be prompted to confi rm the saving of settings if
change is made. Refer section 6.16.