. A complete Parts List is available at www.MillerWelds.com
OM-253392 Page 33
6-7. Enable/Disable Auto−Cratert (Menu 4 Of 10)
1 Adjustment Knob
2 Material Thickness Plus (+)
Button
Follow instructions in Section 6-3 to
enter the setup menu.
Press Material Thickness Plus (+) but-
ton three times after entering setup to
enter the Auto−Crater feature menu.
. Auto−Crater is disabled by
default.
Rotate adjustment knob clockwise to
enable Auto−Crater.
Rotate adjustment knob counterclock-
wise to disable Auto−Crater.
Cycle through menu items using the
Material Thickness Plus (+) button or
cycle unit power to save settings and
exit menu.
. Cycle unit power before welding to
complete initialization process.
Ref. 249 632-F
1
1
2