60
Cut Out Data with Registration Mark
Correct the light pointer position
If the plotter fails to recognize any registration mark properly, the possible cause is an error in the positional
relationship between the MARK sensor and the light pointer.
In this case, adjust the position of the light pointer.
1
Install a cutter in the tool holder.
2
Load the copy paper.
3
Confirm that the plotter is in the local
mode.
4
Press the key.
5
Select [MARK SENSOR] by pressing
the jog key or .
6
Press the key.
7
Select [POINTER OFS] by pressing the
jog key or .
8
Press the key.
A 10 mm by 10 mm cross pattern will be
cutted.
The light pointer turns on and moves to the center of the cross pattern.