2-2  BeneLink Module Operator’s Manual 
2.3 Data transmission 
The Benelink module is connected with external devices via the serial ports (physical 
interfaces are RJ45 connectors). You can simultaneously connect up to four external 
devices via one BeneLink module. Parameters, alarm data from the external devices 
can be output. For BeneVision N Series monitors, respiratory waveforms and loops 
from the external devices can also be output. BeneVision N Series monitors can 
output the parameter measurements, alarm limit settings, and alarm status to 
external devices via the DIAP protocol (Datascope Improved ASCII Protocol). 
2.4 Supported Devices 
Please contact Mindray service personnel for the most recent information on the 
supported devices. 
2.4.1 Supported Anesthesia Machines 
Brand  Model  ID for ID 
adapter 
Type of serial port 
adapting cable 
Draeger  Apollo  444FBBB1  Type C 
Fabius GS  4446BBBA  Type C 
Fabius Tiro  4446BBBA  Type C 
Perseus A500  4435BBCB  None needed 
GE  Aestiva 7900/7100  4F37B0C9  Type D 
Aespire 7900/7100 (for 
BeneVision N Series only) 
4F37B0C9  Type D 
Aespire View (for 
BeneVision N Series only) 
4145bebb  Type D 
Aisys  4F41B0BF  Type D 
Aisys CS2 (for BeneVision N 
Series only) 
4F41B0BF  Type D