5-40 Image Optimization
Tips: the upper part of the 3D image in the D window is corresponding to the orientation mark
on the probe, if the fetal posture is head down (orientating the mother’s feet), and the
orientation mark is orientating the mother’s head, then the fetus posture is head down in the
3D image, you can make the fetus head up by rotating the 3D image by touching [180°] on the
touch screen.
CAUTION:
The ultrasound images are provided for reference only, not for
confirming a diagnosis. Please use caution to avoid misdiagnosis.
Free View (Free View Imaging)
With this function, probe scanning direction can be controlled just by changing the probe
scanning angle, the interested image can be easily found without any actual probe position
and direction change. It not only reduces the operations, but most importantly, it decreases the
discomfort of patients resulted from probe moving.
When the intra-cavity 4D probe is activated, the parameter [Angle] can be adjusted on B
image touch screen for probe angle adjusting.
Range: 45°~+45°; in increments of 5°.
Wire cage
When you view a 3D/4D image on the display monitor, it’s sometimes difficult to recognize the
orientation. To help, the system displays a three-dimensional drawing to illustrate the
orientation. Of which, the blue plane presents the image acquisition where started, while the
red plane presents the image acquisition where ended, besides, a yellow plane in the wire
cage presents the position of the MPR. See the graphic below:
Wire Cage

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray DC-80 and is the answer not in the manual?

Mindray DC-80 Specifications

General IconGeneral
Imaging ModesB, M, Color Doppler, Power Doppler, Pulsed Wave Doppler, Continuous Wave Doppler, Tissue Doppler, 3D/4D Imaging
ProbesConvex, Linear, Phased Array, Volume
Advanced FeaturesAuto Optimization, Auto EF
ConnectivityDICOM 3.0, USB, HDMI, VGA, Ethernet
Transducer Ports4
ApplicationsAbdominal, Cardiac, Obstetrics/Gynecology, Vascular, Small Parts, Musculoskeletal, Urology, Pediatrics, Neonatal
Transducer TypesConvex, Linear, Phased Array, Volume
Power Supply100-240V AC, 50/60Hz
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 60°C
Humidity30% to 80%