6. Operating | 6.2 - Configuration and adjustment via the keypad | 124
Function SPM bit Description
b64 = 1 X64 = 1 Marker bit 1 set, markers are reset after
power on.
b65 = 1 X65 = 1 Marker bit 2 set, markers are reset after
power on.
b66 = 1 X66 = 1 Marker bit 3 set, markers are reset after
power on.
Example:
Output 1: SPM bit [X35 = 1]
Output 1 becomes true (active) if the weight value drops below zero.
Output 2: SPM bit [X33 = 0]
Output 2 remains true (active) as long as the weight does not exceed Max.
Output 3: SPM bit [X36 = 1]
Output 3 becomes true (active) if the weight value goes to zero ±¼ d.