Mitel SIP-DECT Multi-Cell for MiVoice Connect Planning and Installation Guide
11
FEATURE STATUS NOTES
Inbound PSTN
Call to Hunt
Group
Limitation The inbound call to hunt group fails when
SIP-DECT is one of the hunt group
members.
Recommendation: Restrict the number
of codecs to two (in any combination
such as G711U&G711A, G711U&G729
etc). See the JIRA ID for more details.
PLANNING
This section describes how to perform a site survey. The following topics are covered:
• PLANNING OVERVIEW on page 11
• UNDERSTANDING NETWORKING AND POWER REQUIREMENTS on page 12
• UNDERSTANDING ENVIRONMENTAL REQUIREMENTS on page 12
• UNDERSTANDING ARCHITECTURAL IMPACTS TO COVERAGE on page 12
• GATHERING SITE REQUIREMENTS AND INFORMATION on page 15
• CONDUCTING A SITE SURVEY on page 16
• PREPARING A DRAFT INSTALLATION LAYOUT on page 17
• ORDERING EQUIPMENT on page 18
PLANNING OVERVIEW
This overview lists planning steps to complete before installing your Mitel SIP-DECT
Multi-Cell system.
1.
Understand system components and limitations (described in INTRODUCTION – SYSTEM
OVERVIEW on page 8).
2.
Understand networking, power, and environmental requirements (described below).
3.
Understand how architectural features can impact coverage (described below).
4.
Gather requirements and information specific to the installation site (described below).
5.
Conduct a site survey to measure the coverage range and identify equipment needs
(described
below).
6.
Prepare a draft installation layout (described below).
7.
Order components (described below).