Mitel SIP-DECT Multi-Cell for MiVoice Connect Planning and Installation Guide
33
CONFIGURING SIP SETTINGS
Configure the SIP connection to the call server that the OMM must connect to in
the OMM System > SIP menu.
To configure SIP settings:
1. Log into the OMM.
2. Select the Advanced checkbox in the top bar.
3. Click System > SIP.
Enter values for the following:
• Proxy Server: Site
Proxy IP
• Proxy Port: 5060
• Registration
Server: Switch IP
• Registration Port:
5060
• Registration
period: Enter 3600
• You must select
UDP as the
Transport protocol
as TCP and TLS is
not supported.
Use the default RTP settings
unless your installation
requires a different
configuration. For more
information, see RTP settings
section in the
SIP-DECT OM
System Manual,
Administration Guide, Release
8.1.
Use the default DTMF settings
unless your installation
requires a different
configuration.