104
3 MEMORY CONFIGURATION OF THE CPU MODULE
3.4 Files
File operation available
The following lists the file operations which can be executed to each file in the CPU module by external devices.
: Available, : N/A
*1 Modification of data in files, such as read/write from/to file register and execution of the FWRITE/FREAD instruction
*2 When the CPU module is in the STOP state, the file operation is performed by writing the FB file to the programmable controller. In the
RUN state, it is performed by online change. Note that only programs and FB files that are registered in the parameter can be written
when the operating status of the CPU module is RUN.
*3 Available only when the CPU module operation status is STOP/PAUSE. A communication error occurs when operated in the RUN state.
*4 Available only when the CPU module operation status is STOP/PAUSE. When a program tries to perform memory operation while the
CPU module is RUN, the operation is continued after the operation status is changed through remote STOP.
*5 Operation on CPU Module Logging Configuration Tool.
*6 When the operation target is the SD memory card, the operation can be performed even while the CPU module is RUN.
*7 The availability of the online change (the file batch online change of FB files and the global label setting file) differs depending on the
model and firmware version. (Page 119 File batch online change, Page 1008 Added and Enhanced Functions)
When the modules that do not support the online change mentioned above are used, the operation that is performed in the RUN state
continues after the operating status is changed by the remote STOP function.
*8 If the global label that can be accessed from the external device is set and the CPU module is in the RUN state, only read operation is
available.
*9 When the CPU module is in the RUN state, the file operation is available only when the target file is already written to the CPU module.
File type Operation from engineering tool Operation with SLMP and FTP server
function
Operation via
instruction
*1
Write Read Delete Write Read Delete Write Read
Program
*2
*4
*3*6
*3*6
FB file
*2*7
*4
*3*6
*3*6
Parameter
*4
*4
*3*6
*3
Device comment
*4
*3*6
*3*6
Initial device value
*4
*3*6
*3*6
Global label setting file
*7*8*9
*9
*4
*3*6
*3*6
Initial label value
file
Initial global label
value file
*4
*3
*3*6
Initial local label
value file
*4
*3
*3*6
File register
*4
*3
Event history
Device data storage file
*3*6
*3*6
General-purpose data
Data logging
setting file
Common setting
file
*5
*5
*5
Individual setting
file
*5
*5
*5
Memory dump setting file
Remote password
*4
*4
*3*6
*3*6
Faulty database check file
Module-specific backup parameter
*3
*3
System file for backing up CPU
module data
Backup data file for backing up CPU
module data
Device/label data file for backing up
CPU module data
System file for the iQ Sensor Solution
data backup/restoration function
Backup data file for the iQ Sensor
Solution data backup/restoration
function
ODBC server setting file
Database path file