Appendix 1 Error Codes
743
A
3205H Program
execution error
• After the global label setting file
was modified, only the modified
file was written to the
programmable controller. Or,
without writing the modified global
label setting file, only the
sequence program file(s) and FB
file(s) were written to the
programmable controller. (The
global label setting file was not
written to the programmable
controller.)
• After an FB file was modified, only
the modified FB file was written to
the programmable controller. Or,
without writing the modified FB
file, only the program file(s) and
global label setting file were
written. (The modified FB file was
not written to the programmable
controller.)
• After the "Access from External
Device" setting of the global label
setting was changed, only the
global label assignment
information was written to the
programmable controller. Or, after
the "Access from External Device"
setting was changed, only the
sequence program file(s) and FB
file(s) were written to the
programmable controller. (The
global label setting file was not
written.)
• When the "Access from External
Device" setting is not selected, the
sequence program file(s), FB
file(s), and global label setting file
are written to the programmable
controller without initializing the
memory where the global label
assignment information file is
stored.
Stop • Write all the sequence program file(s),
FB file(s), global label setting file, and
global label assignment information file
to the programmable controller.
• If no global label is used, delete the
global label setting file.
• If the "Access from External Device"
setting is not selected, initialize the
memory where the global label
assignment information file is stored,
and write the sequence program file(s),
FB file(s), and global label setting file to
the programmable controller.
Drive/file
information
At power-on,
at RESET, at
STOP RUN
state
3206H Program
execution error
• After the sequence program was
modified, only the modified
sequence program file was written
to the programmable controller.
Or, without writing the modified
sequence program file, only the
initial local label value file was
written to the programmable
controller.
• After the global label setting file
was modified, only the modified
file was written to the
programmable controller. Or,
without writing the modified global
label setting file, only the initial
global label value file was written.
Stop • Write both the sequence program
file(s) and initial local label value file to
the programmable controller.
• Write both the global label setting file
and initial global label value file to the
programmable controller.
• If no initial global label value is used,
delete the initial global label value file.
• If no initial local label value is used,
delete the initial local label value file.
Drive/file
information
At power-on,
at RESET, at
STOP RUN
state
3207H Program
execution error
• The signal flow area to be used in
the FB program cannot be
secured.
Stop • Check the detailed information (drive/
file information) of the error by
executing module diagnostics using
the engineering tool, and identify the
error program file. Then, reduce the
number of instructions that use the
signal flow area of the FB program
used in the sequence program file.
Drive/file
information
At power-on,
at RESET, at
STOP
RUN
sta
te
Error
code
Error name Error details and cause Stop/
continue
Action Detailed
information
Diagnostic
timing