APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
949
A
*1 When the storage destination of the data logging files is the function memory, up to 2 data loggings can be executed simultaneously
even though 10 data loggings can be set.
*2 If the data logging file transfer function is not set, the files are stored in the data memory.
Folder configuration
The following figure shows the folder configuration of the SD memory card attaching to a CPU module.
*1 Folder names cannot be modified.
*2 Do not create folders/files under the $MELPRJ$ and LOGGING folders using a personal computer and other devices.
*3 To remove unnecessary folders, use the following methods:
Use a personal computer.
Logging file operation (Page 990 Logging file operation).
Operation settings when entering into RUN mode This function sets data logging operations when entering into RUN mode
after the data logging setting is registered.
Data logging file transfer function This function automatically transfers data logging files to the FTP server.
SD memory card replacement SD memory cards can be replaced using the SD memory card forced
disable function even when the data logging is in progress.
Item Specifications
$MELPRJ$
LOGGING
/
LOG01
LOG02
LOG03
LOG01.BIN
00000101
00000001
LOG02.BIN
LOG03.BIN
00000001.BIN
00000002.BIN
Stack file (setting No.1)
Stack file (setting No.2)
Stack file (setting No.3)
*1 *2
*1 *2
*3
*3