11 DATA LOGGING FUNCTION
11.1 Data to Be Collected
Devices to be collected
The following table lists the devices that can be specified as the collected data.
*1 An index modified device and indirectly specified device cannot be specified.
*2 For bit devices, digit specification is allowed for K1 to K8 only.
*3 For word devices, bit specification is allowed.
*4 To specify the local device, use "Program name/#Device name". (Example: "MAIN/#M1")
*5 To specify these devices with CPU Module Logging Configuration Tool, use T (contact): TS, T (coil): TC, ST (contact): STS, ST (coil):
STC, C (contact): CS, C (coil): CC, LT (contact): LTS, LT (coil): LTC, LST (contact): LSTS, LST (coil): LSTC, LC (contact): LCS, and LC
(coil): LCC.
*6 The device can be collected by using the CPU module where the SFC function can be used. ( Page 1008 Added and Enhanced
Functions)
Labels to be collected
The following table lists the labels that can be specified to be collected.
*1*2
*1 A label with a name of 256 characters or less can be specified. When the local label is specified (program block name/label name), the
"program block name/" part is counted as the number of characters.
*2 Only labels in the read project of the engineering tool can be specified.
*3 Specify the label with "Program block name/Label name". (Example: "ProgPou/label_w1")
*4 Digit-specified labels cannot be specified.
*5 Bit specification is allowed.
*6 For the label of timer type and counter type, specify the element name. (S: contact, C: coil, N: current value)
Global label example: "label_w1.S"
Local label example: "ProgPou/label_w1.S"
*7 Specify the array element. If the array element is not specified, it is handled as the start of the array ([0]). ( Page 969 Data)
*8 Specify the structure member. ( Page 969 Data)
When specifying a label, save the project of the engineering tool that contains the label in advance because
the project is imported into CPU Module Logging Configuration Tool.
Type Device
*1
Bit device
*2
X, DX, Y, DY, M
*4
, L, F, SM, V
*4
, B, SB, T (contact)
*4*5
, T (coil)
*4*5
, ST (contact)
*4*5
, ST (coil)
*4*5
, C (contact)
*4*5
, C
(coil)
*4*5
, LT (contact)
*4*5
, LT (coil)
*4*5
, LST (contact)
*4*5
, LST (coil)
*4*5
, LC (contact)
*4*5
, LC (coil)
*4*5
, FX, FY, Jn\X, Jn\Y,
Jn\SB, Jn\B, BLn\S
*6
Word device
*3
T (current value)
*4
, ST (current value)
*4
, C (current value)
*4
, D
*4
, SD, W, SW, RD, R, ZR, Z, FD, Un\G, Jn\W, Jn\SW,
U3En\G, U3En\HG
Double-word device LT (current value)
*4
, LST (current value)
*4
, LC (current value)
*4
, LZ
Type Class Data type
Global label VAR_GLOBAL
VAR_GLOBAL_RETAIN
Primitive data type/array
*7
•Bit
*4
Word (signed)
*5
Double word (signed)
Word (unsigned)
*5
Double word (unsigned)
Single-precision real number
Double-precision real number
•Time
•String
Timer type
*6
Retentive timer type
*6
Counter type
*6
Long timer type
*6
Long retentive timer type
*6
Long counter type
*6
Structure
*8
Local label
*3
•VAR
VAR_RETAIN