35 BASIC CONCEPT
35.11 Memory Specifications
587
35
File operation available
This section describes file operations which are available for each file type.
In TEST MODE
The following table lists file operations which are available for each file type in TEST MODE.
: Available, : Not available, : N/A
*1 To write files to the programmable controller, use the write function when the operating status of the SIL2 Process CPU is STOP. When
the operating status is RUN, use the online change function. When the SIL2 Process CPU operating status is RUN, only the standard
programs registered in the CPU parameter can be written to the programmable controller.
*2 Operation is possible only when the operating status of the SIL2 Process CPU is STOP/PAUSE. If any file operation is performed in the
RUN state, the operating status of the SIL2 Process CPU is changed by the remote STOP function, and then the operation continues.
*3 This parameter relates to safety control inside the CPU parameters. ( Page 936 Safety CPU parameters)
This item is yellow in the engineering tool CPU parameters.
*4 Operation is possible only when the operating status of the SIL2 Process CPU is STOP/PAUSE. A communication error occurs when
the file is operated in the RUN state.
File type Operation using engineering tool Operation with SLMP and FTP
server function
Operation with
instructions in
standard programs
Write Read Delete Write Read Delete Write Read
Standard program
*1

*2

Standard FB file
*2

*2

Standard CPU parameter
*2

*2

System parameter
*2

*2

Standard module parameter
*2

*2

Module extension parameter
*2

*2

Module-specific backup parameter 
*4

Memory card parameter
*2

*2

Device comment 
*2

Device initial value 
*2

Standard global label setting file
*2

*2

Label initial
value file
Global label initial
value file

*2

Local label initial
value file

*2

File register 
*2

Event history 
Device data storage file 
General-purpose data 
Remote password
*2

*2

Safety program
*1

*2

Safety FB file
*2

*2

Safety CPU parameter
*3
*2

*2

Safety module parameter
*2

*2

Safety global label setting file
*2

*2

Standard/safety shared label setting
file
*2

*2
