730
APPX
Appendix 1 Error Codes
2441H Module major
error
An error has been detected in the
I/O module or intelligent function
module when the instruction was
executed.
Stop/
continue
Take measures to reduce noise.
Reset the CPU module and run it
again. If the same error code is
displayed again, the possible cause is
a hardware failure of the error module.
Please consult your local Mitsubishi
representative.
Error location
information,
system
configuration
information
At instruction
execution
2442H An error has been detected in the
I/O module or intelligent function
module during the END
processing.
Stop/
continue
System
configuration
information
At module
access
2443H An error has been detected in the
I/O module or intelligent function
module.
Stop
2450H Module major
error
A major error has been notified
from the intelligent function
module connected.
The I/O module or intelligent
function module is not mounted
properly or was removed during
operation.
Stop/
continue
Take measures to reduce noise.
Check the connection status of the
extension cable.
Check the detailed information (system
configuration information) of the error
by executing module diagnostics using
the engineering tool and check the
module corresponding to the displayed
slot number.
Reset the CPU module and run it
again. If the same error code is
displayed again, the possible cause is
a hardware failure of the error module.
Please consult your local Mitsubishi
representative.
System
configuration
information
Always
2460H Another CPU
module major
error
An error has been detected in
another CPU module during the
initial processing.
Stop Take measures to reduce noise.
Reset the CPU module and run it
again. If the same error code is
displayed again, the possible cause is
a hardware failure of the host CPU
module or another CPU module where
the error has been detected. Please
consult your local Mitsubishi
representative.
System
configuration
information
At power-on,
at RESET
2461H An error has been detected in
another CPU module when the
instruction was executed.
Stop/
continue
Error location
information,
system
configuration
information
At instruction
execution
2462H An error has been detected in
another CPU module during the
END processing.
Stop/
continue
System
configuration
information
At END
instruction
execution
2463H An error has been detected in
another CPU module.
Stop System
conf
iguration
information
At power-on,
at RESET
2470H A major error has been notified
from another CPU module.
Stop/
continue
System
configuration
information
Always
2480H Multiple CPU
error
In a multiple CPU system, an error
has been detected in the CPU
module where "Stop" is set in the
operation mode setting parameter.
Any CPU module other than CPU
No.1 is mounted in the
inapplicable slot.
(An error occurs in the CPU module
mounted in the inapplicable slot.)
Stop Check the detailed information (system
configuration information) of the error
by executing module diagnostics using
the engineering tool, identify the error
module, and eliminate the error cause.
Remove the CPU module from the
inapplicable slot.
System
configuration
information
Always
2481H Multiple CPU
error
In a multiple CPU system, any
CPU module other than CPU No.1
was disconnected from the base
unit during operation. Or, any CPU
module other than CPU No.1 was
reset.
Stop Check the mounting status and reset
status of the CPU modules other than
CPU No.1.
System
configuration
information
Always
Error