Appendix 2 Event List
797
A
*1 As for file-related events such as writing and deleting a file, the following files are targeted:
Program file
FB program file
Parameter file
Data logging setting file (common setting file, individual setting file)
Memory dump setting file
When the SIL2 Process CPU or Safety CPU is used, the following files are targeted as well:
Safety program file
Safety FB program file
Safety parameter file
*2 The engineering tool displays "Start-up information" in detailed information 1 only when the Process CPU with firmware version "06"
later or the SIL2 Process CPU is used.
25200 Operation Info System A/B setting
write
The system A/B setting was written to the
CPU modules.
Operation
source
information
System A/B
setting
information
26000 Redundant
operation mode
change (backup
mode)
The operation mode in a redundant
system was changed to backup mode.
26001 Redundant
operation mode
change (separate
mode)
The operation mode in a redundant
system was changed to separate mode.
2A200 Warning Memory
initialization
*1
The memory was initialized. Operation
source
information
Drive/file
information
2A201 Device/label zero
clear
Values in a device or label were cleared
to zero.
Device/label
information
2A202 Folder/file deletion
*1
A folder or file was deleted. Drive/file
information
2A205 Battery-less option
cassette
initialization
The battery-less option cassette was
initialized.
Drive number
and file name
2B000 System switching
(by a user)
The systems were switched due to the
cause on the user side.
System
switching
information
2B001 Memory copy
execution by the
engineering tool
(control system)
The memory copy function was executed
by the engineering tool.
2B002 Memory copy
execution by the
special relay and
special register
(control system)
The memory copy function was executed
by the special relay and special register.
2B003 Memory copy
execution by a user
(standby system)
The memory copy function was executed
by a user.
2B004 Control system
forced start-up
One system was forcibly started as a
control system while waiting for a start-up
of the other system.
Operation
source
information
Control system
start-up cause
information
Event
code
Event
type
Event
category
Detected event Description Detailed information
Detailed
information 1
Detailed
information 2
Detailed
information 3

Table of Contents