APPX
Appendix 5 List of Special Register Areas
841
A
SD113 to
SD143
Detailed
information 2
Detailed
information 2
Detailed information 2 corresponding to the error code (SD0) is stored.
The type of information can be checked in SD112. (The value of the
"Detailed information 2 information category code" stored in SD112
corresponds to the following (2) to (5), (25), (28) and (29).)
(2) Drive number and file name
SD113: With or without specification
b0: Drive number
b1: File name
SD114: Drive number
SD115 to SD122: File name (first eight characters of Unicode string)
(3) Annunciator number
SD113: With or without specification
b0: Annunciator number
SD114: Annunciator number
(4) Parameter information
SD113: With or without specification
b0: Parameter type
b1: Parameter storage location
b2: I/O number
b3: Parameter number
b4: Network number
b5: Station number
b6: System information
S (Error) ALL