972
APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
■Batch insertion of data
The following window is to insert data items into the data list at once. Data is inserted into blank rows in the list of the "Data"
setting window in order from the top (when a setting already exists in the target insertion row, the row is skipped without
overwriting it).
1. Open the following window.
[Edit] [Batch Data Insertion]
2. Configure the setting items and continuous settings, and click the [OK] button.
Item Description Setting range Default
Device Head Specify the start device number. In this field, only global devices can be
input. (Local devices cannot be input.)
Page 171 Data to be
collected
Last In this field, the end device number calculated based on the data type and
size is displayed.
Data type Select a type of the data to be inserted at once. Page 171 Data type
Size Specify the data size when the data type is set to "String" or "Raw". 1 to 256 bytes
Output Format Clicking the [...] button at the rightmost part of each row displays the
"Output Format (integer/float)" window. Select the format to be used when
data is output to the file.
Page 950 Data output type
Continuous
setting
Tot al
number
Specify the total number of data items to be inserted at once. 2 to 128
Interval Specify the device interval of data to be inserted at once. 1 to 268435455