278
20 DATA LOGGING FUNCTION
20.6 Data Logging File
Storage location of data logging files
The storage location of data logging files is an SD memory card. ( CPU Module Logging Configuration Tool Version 1
Operating Manual (MELSEC iQ-R Series))
Folder configuration
The following figure shows the folder configuration of the SD memory card attaching to a CPU module.
*1 Folder names cannot be modified.
*2 Do not create folders/files under the $MELPRJ$ and LOGGING folders using a personal computer and other devices.
*3 To remove unnecessary folders, use the following methods:
Use a personal computer.
Logging File Operation ( CPU Module Logging Configuration Tool Version 1 Operating Manual (MELSEC iQ-R series))
$MELPRJ$
LOGGING
/
LOG01
LOG02
LOG03
LOG01.BIN
00000101
00000001
LOG02.BIN
LOG03.BIN
00000001.BIN
00000002.BIN
Stack file (setting No.1)
Stack file (setting No.2)
Stack file (setting No.3)
*1 *2
*1 *2
*3
*3