710
APPX
Appendix 7 Processing Time
END processing time
The END processing time includes the following:
Common processing time
I/O refresh processing time
Link refresh processing time for the network module
Intelligent function module refresh processing time
Multiple CPU refresh processing time
Prolonged time of END processing when executing each function
Device/label access service processing time
Tracking transfer time ( Page 724 Increase in the scan time due to tracking transfer)
Common processing time
The following table lists the common processing time of each CPU module to be treated by the system.
The common processing time by the system is 85s for one unit of CPU module (module is not mounted).
Condition Common processing time
Process mode Redundant mode
One unit of CPU module (module is not
mounted)
100s190s