588
36 ERROR CODES
36.4 List of Error Codes
3400H Operation error Division where the divisor is zero was
performed.
Stop/
continue
Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Error location
information,
process
control
instruction
processing
information
At instruction
execution
3401H Data that cannot be converted by
using the data conversion instruction
was input.
3402H The operation was performed with the
invalid data (-0, denormalized
number, NaN (not a number), or ).
3403H An overflow has occurred during the
operation.
3404H A string that is not supported in the
instruction was specified.
3405H The input data was out of range.
3406H The operation result is out of the
output range. (The operation result of
the instruction that concatenate
character strings exceeded the
allowable number of characters.)
3420H The link direct device, module access
device, or CPU buffer memory access
device is specified for both (s) and (d)
used in the BMOV instruction.
Error location
information
3421H Operation error When writing data to the data memory
by using the SP.DEVST instruction,
the number of writes per day
exceeded the number set in SD771.
The value set in SD771 is out of
range.
Stop/
continue
Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and check if the
SP.DEVST instruction is used
correctly in the program.
Execute the SP.DEVST instruction
again on another day, or change
the value in SD771.
Set the value in SD771 within the
settable range.
Error location
information
At instruction
execution
3422H Operation error The structure of the PID control
instruction is incorrect.
Stop/
continue
Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the PID control
instruction structure.
Error location
information
At instruction
execution
3423H Operation error The size of data to be sent/received
by the socket communications
instruction exceeds the allowable
range.
Stop/
continue
Check and change the send data
size of the CPU module or the
external device.
If the same error code is displayed
again, the possible cause is a
hardware failure of the CPU
module. Please consult your local
Mitsubishi representative.
Error location
information
At instruction
execution
3424H Operation error A second SFC program was started
with an instruction while an SFC
program was running.
Stop/
continue
Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and check the SFC
program execution status.
E
r
ror location
information
At instruction
execution
Error
code
Error name Error details and cause Stop/
continue
Action Detailed
information
Diagnostic
timing