37 EVENT LIST
37.1 How to Read the Event List
631
37
Detailed information
The following table lists the details of information displayed in the detailed information 1 to 3.
Detailed
information
Item Description
Detailed
information 1
Operation source information Information on the operation source
Connection port (such as Ethernet and USB)
I/O number
CPU number (a number assigned to CPU modules in a multiple CPU system)
Network number
Station number
IP address
Event history file information Information on the event history file
Module information Information on the target module (I/O number)
Firmware update information (RnPCPU) Information (firmware versions before and after update) on the firmware update using an
SD memory card for the RnPCPU
CPU module data backup/restoration
information
Information on the CPU module data backup/restoration function (operation, result, error,
data specification, initialization, latest data, special relay, special register, operation
mode)
CPU module data backup setting information Information on the CPU module backup setting (backup function setting, error codes)
Data backup/restoration information of iQ
Sensor Solution
Information on the data backup/restoration function of iQ Sensor Solution (operation,
target device, execution unit, target module, folder number setting method, total number
of executions, number of successful executions, number of executions completed with an
error, folder number)
Information on the execution status of the data
backup/restoration function of iQ Sensor
Solution
Information on the execution status of the data backup/restoration function of iQ Sensor
Solution (result, error category, error code)
Information on the right to use the data backup/
restoration function of iQ Sensor Solution
Information on the right to use the data backup/restoration function of iQ Sensor Solution
(right-to-use number, operation)
System switching information Information on the system switching cause, the cause of system switching failure, and
the transition state of the systems (control system and standby system)
Start-up information Information on the start-up
Normal start-up
Start-up with SD memory card diagnostics
Information on the initial processing cancellation Information on the initial processing cancellation
SD memory card diagnostics
Extension cable information Information on the base unit to which the extension cable in which the error occurs is
connected
Automatic standby system recovery information Information on the automatic standby system recovery