EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R02CPU - System B IP Address

Mitsubishi Electric MELSEC iQ-R02CPU
416 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 PARAMETER SETTINGS
2.3 Application Settings
277
2
*1 Set in increments of 100ms.
*2 This setting is not available for the CPU module (built-in Ethernet port part).
*3 This setting is not available when the RJ71EN71 network type is set to "Q Compatible Ethernet".
System B IP Address
When the parameters are written without setting the IP address, the following address is set.
System
Connection
*2
Auto-open UDP
Port
Set whether to issue a system switching request when a
communication error occurs using the auto open UDP port. This port is
used when using SLMP communications.
This setting is enabled when the following conditions are met.
The remote password setting is enabled.
The remote password is unlocked.
When the above conditions are not met, even if a communication error
occurs in the target connection, a system switching request will not be
issued.
No System Switching Request at
Communication Error
System Switching Request at
Communication Error
(Default: No System Switching
Request at Communication Error)
MELSOFT
Transmission Port
(UDP/IP)
Set whether to issue a system switching request when a
communication error occurs using the MELSOFT transmission port
(UDP/IP). This port is used when performing UDP/IP communications
with MELSOFT products.
This setting is enabled when the following conditions are met.
The remote password setting is enabled.
The remote password is unlocked.
When the above conditions are not met, even if a communication error
occurs in the target connection, a system switching request will not be
issued.
When "System Switching Request at Communication Error" is
selected, a system switching request is issued even if a communication
error occurs in any of the following ports.
Port used for communications using a dedicated instruction
Relay transmission port with other networks
MELSOFT direct connection port
Direct connection port with the engineering tool
When "No System Switching Request at Communication Error" is
selected, even if a communication error occurs in any of the above
ports, a system switching request will not be issued.
No System Switching Request at
Communication Error
System Switching Request at
Communication Error
(Default: No System Switching
Request at Communication Error)
MELSOFT
Transmission Port
(TCP/IP)
Set whether to issue a system switching request when a
communication error occurs using the MELSOFT transmission port
(TCP/IP). This port is used when performing TCP/IP communications
with MELSOFT products.
No System Switching Request at
Communication Error
System Switching Request at
Communication Error
(Default: No System Switching
Request at Communication Error)
FTP Transmission
Port (TCP/IP)
Set whether to issue a system switching request when a
communication error occurs using the FTP transmission port (TCP/IP).
This port is used for the file transfer function (FTP server).
No System Switching Request at
Communication Error
System Switching Request at
Communication Error
(Default: No System Switching
Request at Communication Error)
Module IP address
RJ71EN71 P1 connector 192.168.3.42
P2 connector 192.168.4.42
CPU module (built-in Ethernet port part) 192.168.3.41
Item Description Setting range

Table of Contents