Appendix 3 Buffer Memory
When using the RJ71EN71 (network type: Q-compatible Ethernet)
With the Q-compatible Ethernet, the same buffer memory addresses as the MELSEC-Q series Ethernet interface module can
be used, excluding some addresses.
■Buffer memory addresses usable only with RJ71EN71
The following table lists the buffer memory addresses that can be used only with RJ71EN71.
■Buffer memory addresses differing from MELSEC-Q series Ethernet interface modules
The following table lists the buffer memory addresses having specifications that differ from the ones of the MELSEC-Q series
Ethernet interface module.
Address Application Name
Decimal Hexadecimal
20700 to
20701
50DCH to
50DDH
Forced connection
invalidation
Forced connection invalidation specification
20700 (b0 to 15): Connection No.1 to 16
20701 (b0): Auto-open UDP port
20701 (b1): MELSOFT transmission port (UDP/IP)
20701 (b2): MELSOFT transmission port (TCP/IP)
20701 (b3): FTP transmission port
65535 FFFFH Network type
information
Network type information
Address Name
Decimal Hexadecimal MELSEC-Q series Ethernet interface module RJ71EN71
0 to 1 0H to 1H Own station E71 IP address
Initial value: C00001FEH
Own station IP address
Initial value: C0A80328H
4 4H Special function settings
Initial value: 100H
Special function settings
Initial value: 10H
31 1FH Communication condition setting (Ethernet Operation
Setting) area
Initial value: 0H
Communication data code setting (b1)
0: Communications in a binary code
1: Communications in an ASCII code
TCP existence confirmation setting (b4)
0: Use the Ping
1: Use the KeepAlive
Send frame setting (b5)
0: Ethernet
1: IEEE 802.3
Setting of write enable/disable at RUN time (b6)
0: Disable
1: Enable
Initial timing setting (b8)
0: Do not wait for OPEN (Communications impossible at
STOP time)
1: Always wait for OPEN (Communication possible at
STOP time)
Reinitialization specification (b15)
0: Reinitialization process complete (reset by the system)
1: Reinitialization process request (set by the user)
Communication condition setting area
Initial value: 100H
Communication data code (b1)
0: Binary
1: ASCII
Enable/disable online change (b6)
0: Disable all (SLMP)
1: Enable all (SLMP)
Opening method (b8)
0: Open by program
1: Do not open by program
Reinitialization specification (b15)
0: Reinitialization process complete (reset by the system)
1: Reinitialization process request (set by the user)
40 28H Communication address
setting area
Connection No.1
Own station port No.
Initial value: 0H
Communication address
setting area
Connection No.1
Own station port No.
Initial value: 0H
41 to 42 29H to 2AH Destination IP address
Initial value: 0H
Destination IP address
Initial value: 0H
43 2BH Destination Port No.
Initial value: 0H
Destination Port No.
Initial value: 0H
44 to 46 2CH to 2EH Destination MAC address
Initial value:
FFFFFFFFFFFFH
System area
47 to 95 2FH to 5FH Communication address setting area Connection No.2 to 8
(Same as connection No.1)
Communication address setting area Connection No.2 to 8
(Same as connection No.1)
106 to 107 6AH to 6BH Own station IP address
Initial value: 0H
Own station IP address
Initial value: C0A80328H