406
APPX
Appendix 13 Added and Enhanced Functions
Appendix 13Added and Enhanced Functions
The following table lists the added and enhanced functions in the Ethernet-equipped module.
: Available (No version restriction), : Not available
*1 'Receive buffer full detection signal' (Un\G21056) can be used when the network type is set to "Q Compatible Ethernet".
*2 Refer to the following.
iQ Sensor Solution Reference Manual
*3 There are restrictions on the CPU module to be used. For details, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Application)
*4 Only the following models can be used. The supporting firmware version differs depending on the model.
Process CPU: "04" or later
SIL2 Process CPU: There are no restrictions on the version.
*5 Only the programmable controller CPU can be used. For the R00CPU, R01CPU, and R02CPU, there are no restrictions on the version.
*6 Only the following models can be used. The supporting firmware version differs depending on the model.
R00CPU, R01CPU, R02CPU: There are no restrictions on the version.
Programmable controller CPU (except for R00CPU, R01CPU, and R02CPU): "22" or later
Process CPU: "13" or later
*7 Only the following models can be used. The supporting firmware version differs depending on the model.
R00CPU, R01CPU, R02CPU: "05" or later
Programmable controller CPUs other than the above: "35" or later
*8 Only the following models can be used. The supporting firmware version differs depending on the model.
R00CPU, R01CPU, R02CPU: "08" or later
Programmable controller CPUs other than the above: "40" or later
Added and enhanced function Firmware version
RJ71EN71 RnENCPU
(network part)
CPU module
(built-in Ethernet
port part)
Turning off the LED with the ERRCLEAR instruction "05" or later 
'State of receive buffer' (Un\G1900030)
*1
"05" or later 
Automatic detection of connected devices
Communication setting reflection
Sensor parameter read/write

*2
IP address change function "10" or later "10" or later
Redundant system function
*3
"12" or later
*4
Remote head module redundant system "12" or later 
File transfer function (FTP client) 
*6
High-speed write mode (File transfer function (FTP server)) "23" or later
*5
Accessing to another station via the port 1 and port 2 using SLMP communications "18" or later 
Simple CPU communication function "35" or later "35" or later
*7
Communications by network number/station number 
*8
MODBUS/TCP slave function "35" or later "35" or later
Simple CPU communication function for MELSEC iQ-F series "35" or later "35" or later
*8