386
APPX
Appendix 6 Communications with Different Networks
When the networks consist of only MELSEC iQ-R series
Communication paths are automatically set for communication with the following networks of MELSEC iQ-R series.
Ethernet
CC-Link IE Controller Network
CC-Link IE Field Network
Setting procedure
Use the following procedure.
1. Set the network number, station number, and transient transmission group number in the "Own Node Settings" under
"Basic Settings". ( Page 243 Communications by Network No./Station No.)
2. Set the "Network Dynamic Routing" under "Application Settings" to "Enable".
Communication paths are automatically set, but they can also be manually set. To set communication paths
manually, refer to the following. ( Page 386 When the networks consist of MELSEC iQ-R series and
other series)
The communication path cannot be set automatically for Ethernet-equipped modules connected via a
router. Set the communication path manually. ( Page 386 When the networks consist of MELSEC iQ-R
series and other series)
When the networks consist of MELSEC iQ-R series and other series
Setting communication paths allows communication with the following networks configured with modules other than MELSEC
iQ-R series.
Ethernet
CC-Link IE Controller Network
CC-Link IE Field Network
MELSECNET/H
MELSECNET/10
Setting procedure
Use the following procedure.
1. Set the network number, station number, and transient transmission group number in the "Own Node Settings" under
"Basic Settings". ( Page 243 Communications by Network No./Station No.)
2. Set the send destination station information in "Network/Station No. <-> IP information setting" under "Application
Settings". ( Page 265 Network/Station No. <-> IP information setting)
3. Set communication paths in "Routing Setting" of "CPU Parameter".
( MELSEC iQ-R CPU Module User's Manual (Application))