EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q Series - Page 488

Mitsubishi Electric MELSEC-Q Series
624 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 - 43
7 AUXILIARY AND APPLIED FUNCTIONS
(3) Cautions
(a) In the following cases acceleration time or deceleration time does not
change when a speed change is executed. The acceleration time or
deceleration time at the time of speed change accept is maintained.
• When setting of the acceleration/deceleration time change enable device
was omitted.
• When setting of new acceleration time value device or new deceleration
time value device was omitted.
• When the device set by new acceleration time value device or new
deceleration time value device is set to "0".
Decelerate at
deceleration time
after change
0
t
V
500
OFF
ON
Acceleration/deceleration
time change enable device
New acceleration time
value device
New deceleration time
value device
Speed change request
(CHGV)
OFF
ON
Change of acceleration
time is not executed
0
(b) During interpolation control, change of acceleration/deceleration time is
executed by the acceleration/deceleration time change parameter of the axis
No. specified with the speed change command.
(c) Acceleration/deceleration time change function becomes invalid for axes
executing the following servo instructions:
• Circular interpolation control (including point during CPSTART)
• Helical interpolation control (including point during CPSTART)
• Speed control with fixed position stop
(d) Acceleration/deceleration time change function becomes invalid for axes
executing the following acceleration/deceleration methods:
• FIN acceleration/deceleration
• Advanced S-curve acceleration/deceleration control

Table of Contents

Other manuals for Mitsubishi Electric MELSEC-Q Series

Related product manuals