EasyManua.ls Logo

Mitsubishi Melsec-A AJ65SBT - Page 19

Mitsubishi Melsec-A AJ65SBT
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 - 6 2 - 6
MELSEC-
A
2 SYSTEM CONFIGURATION
2) Preventive measure against incorrect input
Install wiring so that the power is supplied from the same power
source to the power supply module, stabilized power supply and
external power supply for AC input.
DC input
AJ65SBT-CLB
24VDC
24VDC
Stabilized
power supply
Stabilized
power supply
Power supply
adapter
External
supply
power
for input
Remote I/O module
AC input
24VDC
Stabilized
power supply
Power supply
adapter
Remote I/O module
AJ65SBT-CLB
External
supply
power
for input

Table of Contents