6 - 3                         6 - 3 
MELSEC-
6   TROUBLESHOOTING 
 
6.3 Troubleshooting when the "ERR" LED on the Master Station is Flashing 
 
To the next page
The "ERR" LED on the  
master station is flickering
Is the  
parameter setting consistent 
with the mounting system  
configuration? 
Are the  
master station  
link special registers  
SW0080 to SW0083  
(other station data  
link status) 
on?
YES
NO
YES
YES
YES
Check the modules in which  
SW0098 to SW009B are on.
Are the station  
number switches
set correctly?
Corresponding module failure
Master station failure
Set the station number
switches correctly.
Power on again/press the 
reset switch.
Check the modules in which 
SW0080 to SW0083 are on.
Is the power supply on?
Is the "POWER" LED on?
Is the "RD" LED on?
Power on.
Is the 
supplied voltage within the 
specified range?
Set the supplied voltage  
within the specified range.
Wire the communication
cable correctly.
To the next page
To the next page
Malfunction of the  
corresponding module
Corresponding module failure
Are the  
master station  
link special registers  
SW0098 to SW009B  
(station overlap  
status) on?
Check the master side.
Check the slave station side
NO
NO
YES
NO
NO
YES
YES
NO
NO
NO
YES
YES
NO
Does 
the corresponding bit 
indicate the AJ65SBT-
CLB?
YES
Refer to Section 6.4 
or later.
NO
Modification of parameter setting 
or mounting system configuration
Is the  
communication cable
correctly installed? 
 1