EasyManuals Logo

Mitsubishi MELSEC User Manual

Mitsubishi MELSEC
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
12 - 74
12.7 Special Register List
12
TROUBLESHOOTING
Table12.19 Special register
Number Name Meaning Explanation
Set by
(When set)
Corresponding
CPU
SD5
Error
common
information
Error common
information
3) Time (value set)
4) Program error location
*4: "0" is stored to the block number and the step number.
9) CC-Link Safety information
*5: The error classification and error item are stored only when
the error code is 8300 (CC-LINK REMOTE DETECTION
ERROR).
0 is stored when the error coad is other than 8300.
10) Module No./Station No.
S (Error) QS
SD6
SD7
SD8
SD9
SD10
SD11
SD12
SD13
SD14
SD15
SD5
SD6
SD7
SD8
SD9
SD10
SD11
SD12
SD13
SD14
SD15
Number Meaning
Time : 1 s units (0 to 999 s)
Time : 1ms units (0 to 65535ms)
(Empty)
SD5
SD6
SD7
SD8
SD9
SD10
SD11
SD12
SD13
SD14
SD15
3
Number
Meaning
File name
(ASCII code: 8 characters)
Extension
2E
H(.)
(ASCII code: 3 characters)
(Empty)
Block No.
Step No.
Sequence step No. (L)
Sequence step No. (H)
4
4
SD6
SD7
SD8
SD9
SD10
SD11
SD12
SD13
SD14
SD15
SD16
Meaning
System area 1
System area 2
System area 3
System area 4
System area 5
System area 6
System area 7
System area 8
Number
Error classification
Error item
Link ID
Station No.
SD5
5
5
SD6
SD7
SD8
SD9
SD10
SD11
SD12
SD13
SD14
SD15
Meaning
(Empty)
Number
Slot No.
I/O No.
Station No.
SD5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC and is the answer not in the manual?

Mitsubishi MELSEC Specifications

General IconGeneral
CategoryProgrammable Logic Controller (PLC)
ManufacturerMitsubishi Electric
SeriesMELSEC
Programming LanguagesLadder Diagram (LD), Function Block Diagram (FBD), Structured Text (ST), Instruction List (IL), Sequential Function Chart (SFC)
Communication ProtocolsEthernet, CC-Link, RS-232, RS-485, USB, Profibus, Modbus
Model SeriesFX, Q, L, iQ-R, iQ-F
Input Voltage100-240V AC, 24V DC (varies by model)
Memory CapacityVaries widely depending on the CPU module and series. Ranges from kilobytes to megabytes.
I/O Points16 to 8192 points (varies by model)
Communication PortsEthernet, RS-232, RS-485, USB (varies by model)
Programming SoftwareGX Works2, GX Works3, GX Developer
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 75°C
Humidity5% to 95% (non-condensing)
Vibration Resistance10 to 57Hz, 0.075mm amplitude; 57 to 150Hz, 9.8m/s² acceleration
Shock Resistance147m/s², 3 times in each direction (X, Y, Z)
Protection ClassIP20 (varies by model)
CPU Processing Speed0.02μs to 0.1μs per instruction (varies by model)