7. PARAMETERS
7 - 33
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
Control
mode
CP CL
PB45
CNHF
Command
notch filter
Set the command notch filter.
_ _ x x Command notch filter setting frequency selection
Refer to table 7.6 for the relation of setting values to frequency.
00h
_ x _ _ Notch depth selection
Refer to table 7.7 for details.
0h
x _ _ _ For manufacturer setting 0h
Table 7.6 Command notch filter setting frequency selection
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
_ _ 0 0 Disabled _ _ 2 0 70 _ _ 4 0 17.6
_ _ 0 1 2250 _ _ 2 1 66 _ _ 4 1 16.5
_ _ 0 2 1125 _ _ 2 2 62 _ _ 4 2 15.6
_ _ 0 3 750 _ _ 2 3 59 _ _ 4 3 14.8
_ _ 0 4 562 _ _ 2 4 56 _ _ 4 4 14.1
_ _ 0 5 450 _ _ 2 5 53 _ _ 4 5 13.4
_ _ 0 6 375 _ _ 2 6 51 _ _ 4 6 12.8
_ _ 0 7 321 _ _ 2 7 48 _ _ 4 7 12.2
_ _ 0 8 281 _ _ 2 8 46 _ _ 4 8 11.7
_ _ 0 9 250 _ _ 2 9 45 _ _ 4 9 11.3
_ _ 0 A 225 _ _ 2 A 43 _ _ 4 A 10.8
_ _ 0 B 204 _ _ 2 B 41 _ _ 4 B 10.4
_ _ 0 C 187 _ _ 2 C 40 _ _ 4 C 10
_ _ 0 D 173 _ _ 2 D 38 _ _ 4 D 9.7
_ _ 0 E 160 _ _ 2 E 37 _ _ 4 E 9.4
_ _ 0 F 150 _ _ 2 F 36 _ _ 4 F 9.1
_ _ 1 0 140 _ _ 3 0 35.2 _ _ 5 0 8.8
_ _ 1 1 132 _ _ 3 1 33.1 _ _ 5 1 8.3
_ _ 1 2 125 _ _ 3 2 31.3 _ _ 5 2 7.8
_ _ 1 3 118 _ _ 3 3 29.6 _ _ 5 3 7.4
_ _ 1 4 112 _ _ 3 4 28.1 _ _ 5 4 7.0
_ _ 1 5 107 _ _ 3 5 26.8 _ _ 5 5 6.7
_ _ 1 6 102 _ _ 3 6 25.6 _ _ 5 6 6.4
_ _ 1 7 97 _ _ 3 7 24.5 _ _ 5 7 6.1
_ _ 1 8 93 _ _ 3 8 23.4 _ _ 5 8 5.9
_ _ 1 9 90 _ _ 3 9 22.5 _ _ 5 9 5.6
_ _ 1 A 86 _ _ 3 A 21.6 _ _ 5 A 5.4
_ _ 1 B 83 _ _ 3 B 20.8 _ _ 5 B 5.2
_ _ 1 C 80 _ _ 3 C 20.1 _ _ 5 C 5.0
_ _ 1 D 77 _ _ 3 D 19.4 _ _ 5 D 4.9
_ _ 1 E 75 _ _ 3 E 18.8 _ _ 5 E 4.7
_ _ 1 F 72 _ _ 3 F 18.2 _ _ 5 F 4.5
Table 7.7 Notch depth selection
Setting
value
Depth [dB]
Setting
value
Depth [dB]
_ 0 _ _ -40.0 _ 8 _ _ -6.0
_ 1 _ _ -24.1 _ 9 _ _ -5.0
_ 2 _ _ -18.1 _ A _ _ -4.1
_ 3 _ _ -14.5 _ B _ _ -3.3
_ 4 _ _ -12.0 _ C _ _ -2.5
_ 5 _ _ -10.1 _ D _ _ -1.8
_ 6 _ _ -8.5 _ E _ _ -1.2
_ 7 _ _ -7.2 _ F _ _ -0.6