10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL) 
 
10 -  3 
 
Command  Data No.  Description  Status display 
Control 
mode 
Frame 
length 
CP CL 
[0] [1]  [8] [0]  Status display data value and 
processing information 
Cumulative feedback pulses 
   
12 
  [8] [1]  Servo motor speed 
   
  [8] [2]    Droop pulses 
   
  [8] [3]    Cumulative command pulses     
  [8] [4]    Command pulse frequency     
  [8] [5]    Analog speed command voltage 
Analog speed limit voltage 
 
  [8] [6]    Analog torque limit voltage 
Analog torque command voltage 
 
  [8] [7]    Regenerative load ratio 
   
  [8] [8]    Effective load ratio 
   
  [8] [9]    Peak load ratio 
   
  [8] [A]    Instantaneous torque 
   
  [8] [B]    Position within one-revolution 
   
  [8] [C]    ABS counter 
   
  [8] [D]    Load to motor inertia ratio 
   
  [8] [E]    Bus voltage 
   
  [A] [0]    Internal temperature of encoder 
   
 
  [A] [1]    Settling time 
   
 
  [A] [2]    Oscillation detection frequency 
   
 
  [A] [3]    Number of tough drive operations 
   
 
  [A] [8]    Unit power consumption 
   
 
  [A] [9]    Unit total power consumption 
   
 
  [A] [A]    Current position 
   
 
  [A] [B]    Command position 
   
 
  [A] [C]    Command remaining distance 
   
 
  [A] [D]    Point table No./Program No. 
   
 
  [A] [E]    Step No.   
 
 
  [A] [F]    Analog override voltage 
   
 
  [B] [0]    Override level 
   
 
  [B] [3]    Cam axis one cycle current value 
   
 
  [B] [4]    Cam standard position 
   
 
  [B] [5]    Cam axis feed current value 
   
 
  [B] [6]    Cam No. in execution 
   
 
  [B] [7]    Cam stroke amount in execution 
   
 
  [B] [8]    Main axis current value 
   
 
  [B] [9]    Main axis one cycle current value