4. HOW TO USE THE POINT TABLE
4 - 9
a) When using the Rotation direction specifying ([Pr. PT03] = "_ 0 _ _")
When the position data of 270.000 degrees is specified, the servo motor rotates in the CCW
direction.
Target
position
Current
position
(270)
When the position data of -90.000 degrees is specified, the servo motor rotates in the CW
direction.
Target
position
Current
position
(-90)
When the position data of -360.000 degrees is specified, the servo motor rotates in the CW
direction. (A)
When the position data of 360.000 degrees or 0 degree is specified, the servo motor rotates in
the CCW direction. (B)
Target
position
Current
position
(B)
(A)
(-360)