EasyManuals Logo

Mitsubishi QJ71BR11 User Manual

Mitsubishi QJ71BR11
422 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #385 background imageLoading...
Page #385 background image
App - 17 App - 17
MELSEC-Q
APPENDIX
Table 2 Link special register (SW) list (Continued)
Use permitted/prohibited
Control
station
Normal
station
Remote
master
station
Remote I/O
station
No. Name Description
Optical Coaxial Optical Coaxial Optical Coaxial Optical Coaxial
2
SW006B
(107)
Maximum link scan time
2
SW006C
(108)
Minimum link scan time
2
SW006D
(109)
Current link scan time
Stores the maximum/minimum/current values of the link scan
time (unit (ms)).
The values for the control station and normal stations vary.
Sequence scan
Link scan
Control station/
normal station
0END0END
(PLC to PLC network)
Normal station Constant link scan that has been set
When the constant scan is set, the values are as follows:
Control station
(Setting value) <
Measured link scan value + KB of the link scan
time equation
(Setting value) >
Measured link scan value + KB of the link scan time equation
Measured link scan value + KB of the link scan
time equation
Measured link scan value
Link scan
Remote I/O station
Remote master station
Sequence scan
0END
0
END
(Remote I/O network)
2
SW006E
(110)
Low-speed cyclic scan
time
Stores the number of link scans in the send interval of the low-
speed cyclic transmission.
Low-speed cyclic
send request
Link scan
Low-speed cyclic
transmission
123456
1
234
Send interval
2
SW0070
(112)/
SW0071
(113)/
SW0072
(114)/
SW0073
(115)
Baton pass status of each
station
Stores the baton pass status of each station (Including the host).
<Online>
0: Normal (including the stations with the maximum station
number and smaller numbers as well as reserved stations)
1: Abnormal
<Offline test>
0: Normal
1: Abnormal (including the stations with the maximum station
number and smaller numbers as well as reserved stations)
16
32
48
64
15 14 13 5 4 3 2 1
31 30
47 46
63 62
29
45
61
21 20 19 18 17
37 36 35
34
33
53 52 51 50 49
to
to
to
to
b15 b14 b13 b12 b4 b3 b2 b1 b0
SW0070
SW0071
SW0072
SW0073
to
Numbers 1 to 64 in the above table
indicate the station numbers.
2: Valid only when SB0047 is off. When it turns on (error), the last data are retained.