Important:
Redundant NTP Multicast time server:
If in the same network two NTP servers should send NTP with the same
Multicast IP address (redundancy), then the first time server has to be
configured with a small pollinterval (e.g. 2 4 sec.) and the second time
server with a large pollinterval (min. 100 x larger, e.g. 9 512 seconds).
As long as the first time server is sending NTP Multicast packets, the
packets from second time server are ignored. This configuration is
needed, to reach a defined situation for the end devices (the DTS
480x.masterclock with the more frequently NTP send rate gets higher
priority for time reception).
Time zone table for the NTP slave clock line:
Display of all time zone entries (15) of time zone servers for NTP slave clock lines.
Choose a zone number to change selected zone.
Time zone selection (see chapter “6.5.28 Time zone selection“)
The page can be exited with 99. Changes are first stored or reset on the overlying
menu page.