6.5.12 General time configuration
1. Stratum limit for synchalarm:
Stratum limit (1-16) for generating the alarm „Failure time source Str“.
Default value: 5.
Explanation:
If the stratum of the DTS 480x is higher or equal than the value
"Stratum limits for synchalarm", then after a fix delay of 1 min the alarm
"Failure time source Str" occurs sync LED turns off !
2. Mode leap second:
0 Off
1 Additional second is added to the time period set
Is set to 0=off after adding the leap second.
-1 A second is omitted at the time period set.
Is set to 0=off after adding the leap second.
2 Recognize leap second automatically. Only possible in the case of a source
notifying the leap second!
3. Set period of time for the leap second in UTC with the format: “hh:mm:ss
TT.MM.YY“. The next usual time will be displayed as a proposal.
Description of leap second see chapter “8.6 Leap Second“.