01/02 AWB8230-1413GB
Acceleration and deceleration
characteristics
131
A098 Deceleration
characteristic
– – 00 Linear deceleration of the motor at the first and second time
ramps
00
01 S-curve characteristic for deceleration of the motor at the
first and second time ramps
02 U-curve characteristic for deceleration of the motor at the
first and second time ramps
03 Inverted U-curve characteristic for deceleration of the motor
at the first and second time ramps
A131 Curvature of
acceleration
characteristic
– j 01 Smallest curvature of the acceleration ramp 02
...
10 Largest curvature of the acceleration ramp
A132 Curvature of
deceleration
characteristic
– j 01 Smallest curvature of the deceleration ramp 02
...
10 Largest curvature of the deceleration ramp
PNU Name
Adjustable in RUN mode Value Function WE
Normal Extended
efesotomasyon.com - Klockner Moeller - inverter