01/02 AWB8230-1413GB
Motor data
149
Type of motor stop
Specify here, how the motor is to decelerate when the OFF button
is pressed:
Fan control
With PNU b092, you can specify when the fan will operate.
If you enter the value 01 here, the fan runs for one minute after
the frequency inverter power supply is switched on, allowing you
to make sure that the fan is working correctly. The fan also
continues to run for five minutes after the connected motor has
stopped to dissipate residual heat.
Debug mode
Under PNU C091, set debug mode.
Motor data
To ensure that the DF6 frequency inverter controls the motor
correctly and generates the greatest possible torque, you can enter
the following motor data:
Motor rating
Number of motor poles
Motor stabilization constant
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
b091 Type of motor
stop
00 Deceleration using the deceleration ramp 00
01 Free run stop (coasting)
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
b092 Fan control 00 Fan is always switched on 00
01 Fan is switched on only while the connected motor is
running.
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
C091 Debug mode j 00 Debug mode is displayed. 00
01 Debug mode is not displayed.
PNU Name Adjustable in RUN mode Value Function WE
Normal Extended
H003
H203
Motor rating 0.2 to 160 kW Enter the motor rating.
0.2 to 75 kW DF6-340-11K to DF6-340-55K
0.2 to 160 kW: from DF6-340-75K
Depen-
ding on
DF6
H004
H204
Number of
motor poles
2/4/6/8 Enter the number of motor poles 4
H006
H206
Motor
stabilization
constant
j j 0 to 255 0 function is not active 100