Programming the Control
Signal Terminals
01/02 AWB8230-1413GB
84
Use second parameter set (SET)
When the digital input configured as SET is active, the parameters
from the second parameter set are used. This allows you to
operate a second motor with the same frequency inverter (albeit
not at the same time) without having to reprogram the frequency
inverter. The functions which are also available in the second
parameter set are listed in table 16.
As soon as the SET input is deactivated, the normal parameters of
the default parameter set are used.
X Program one of the digital inputs 1 to 5 as SET, by setting the
corresponding PNU (C001 to C005) to 08.
The motor must have come to a standstill before the SET input is
activated.
If the SET input is deactivated while the motor is in operation, the
parameters of the second parameter set are used until the motor
is stationary again.
Table 16: Functions with second parameter set
Figure 75: Digital input FW configured as FWD (start/stop clockwise
operation), 3 as SET (use second parameter set) and 5 as
REV (start/stop anticlockwise operation)
REV
FWD
SET
P24FW35
Description of the function Parameter number (PNU)
Default second parameter set
First acceleration time F002 F202
First deceleration time
F003 F203
Base frequency
A003 A203
Maximum end frequency
A004 A204
Frequency setpoint (PNU A001 must be 02 for this)
A020 A220
Voltage boost characteristics
A041 A241
Percentage voltage increase with manual boost
A042 A242
Maximum boost relative to the base frequency
A043 A243
V/f characteristic
A044 A244
Maximum operating frequency
A061 A261
Minimum operating frequency
A062 A262
Second acceleration time
A092 A292
Second deceleration time
A093 A293
Type of changeover from first to second time ramp
A094 A294
Changeover frequency for changeover from first to second acceleration time
A095 A295
Changeover frequency for changeover from first to second deceleration time
A096 A296
Tripping current for electronic motor protection device
b012 b212
Characteristic for electronic motor protection device
b013 b213
Motor rating
H003 H203
Number of motor poles
H004 H204