IP67 IO-Link Modules for EtherNet/IP
Assembly #112 - Digital data + with 8 bytes data per IO-Link device
Input Process Data (8 bytes)
Offset (in byte) per IO-Link channel
IO-Link Process Data (8 bytes)
IO-Link Input Process Data (8 bytes)
IOLS (Bits 0-14) + IOLD (bit 15) (2 bytes)
For Input & IO-Link Process Data information, refer to input assembly #110 & assembly #111
Assembly #113 - Digital data + with 32 bytes data per IO-Link device
Input Process Data (32 bytes)
Offset (in byte) per IO-Link channel
IO-Link Process Data (32 bytes)
IO-Link Input Process Data (32 bytes)
IOLS (Bits 0-14) + IOLD (bit 15) (2 bytes)
For Input & IO-Link Process Data information, refer to input assembly #110 & assembly #111
Warning!
If the IO-Link Input Process Data size configured (ex: 4 bytes) is lower than the IO-Link
Input Process Data size of the connected IO-Link device (ex: 32 bytes), the EtherNet/IP
connection will be established and the first 4 input bytes of data will be consumed.