A.1.3 Current carrying capacity, Size 5 to Size 6A, air cooling
Servo drive
Power
stage
switching
frequency
Ambient
tempera-
ture
At mains voltage 400 V At mains voltage 460 V At mains voltage 480 V
Overload
factor
≥5Hz
For time
1)
Rated
current
Peak current [Aeff]
2)
Rated
current
Peak current [Aeff]
2)
Rated
current
Peak current [Aeff]
2)
At rotating eld
frequency increas-
ing linearly
During
inter-
mittent
opera-
tion
At rotating eld
frequency increas-
ing linearly
During
inter-
mittent
opera-
tion
At rotating eld
frequency increas-
ing linearly
During
inter-
mittent
opera-
tion
[kHz] [°C]/[°F] [Aeff] 0 Hz
Up to 5
Hz
>5 Hz [Aeff] 0 Hz
Up to 5
Hz
>5 Hz [Aeff] 0 Hz
Up to 5
Hz
>5 Hz [%] [s]
G392-045
(Size 5)
4
+45
(+113)
45 90 90 42 83 84 41 81 82
200 3/10
3)
8
+40
(+104)
45 90 90 42 83 84 41 81 82
12 45 90 90 42 83 84 41 81 82
16 42 84 84 39 78 78 38 76 76
G392-060
(Size 5)
4
+45
(+113)
60 120 120 56 111 112 54 108 108
200 3/10
3)
8
+40
(+104)
60 120 120 56 111 112 54 108 108
12 58 116 116 54 107 108 52 104 104
16 42 84 84 39 78 78 38 76 76
G392-072
(Size 5)
4
+45
(+113)
72 144 144 67 133 134 65 130 130
200 3/10
3)
8
+40
(+104)
72 144 144 67 133 134 65 130 130
12
4)
58 116 116 54 107 108 52 104 104
16
4)
42 84 84 39 78 78 38 76 76
All data apply for a motor cable length ≤10 m (32.80 ft).
1) Shutdown as per I²t characteristic
2) Permissible peak current at maximum 70% initial load
3) 10s at heat sink temperature <+45 °C (+113 °F)
4) For G392 Size 5-Safety only allowed up to 8 kHz
Table A.3 Rated and peak current, Size 5 (air cooling)