MOTOMAN 4-1 Spot Welding Manual for Medar
SECTION 4
SETUP AND OPERATION
This section provides instructions for setting up the spot welding simple and
enhanced weld schedules for welding under normal conditions. It also includes
instructions for setting up stepper condition files.
For general spot welding operating instructions, refer to the Operator’s Manual for
Spot Welding (142101-1). For specific operating information for the spot welding
servo gun, refer to the Motor Gun Function Manual (142972-1).
4.1 Setting Up Parameters
Table 4-1 lists the Medar Timer parameters.
* On a new system, do not change this parameter to “1” until after initial system startup.
To set up parameters S2C370, S2C371, and S2C373, enter Management mode and
follow these instructions:
1. From the XRC Main Menu, select PARAMETER.
2. The following screen appears. Select S2C.
Table 4-1 Medar Timer Parameter List
Parameter Default Function Settings
SC2368 188 Universal Input for Upload-
ing Dynamic Data
N/A
S2C369 187 Universal Input for Resetting
Stepper to Step #2
N/A
S2C370 0 Weld Schedule Edit Security 0: Edit Mode
1: Management Mode
S2C371 0 Weld Schedule Type 0: ACC Simple
2: ACC Enhanced
S2C372 0 Network Address N/A
S2C373 0 Welder Type 0: AC
1: MFDC
S2C374 5 Download Timer for Error
Checking
N/A
S2C378 0 Medar Setup File
(downloaded at startup)
0: No Setup File Downloaded*
1: Setup File Downloaded
S2C379 0 Clear Memory for Debugging 0: Normal
1: Clear Memory at Next Bootup
R1
S
C
L
RS
S1CxG
S3C
S4C
FD
S2C
A1P
!
C10