193
Field Definitions
VRM100 Pager ID This field will be visible only if VRM100 operation has been enabled for the
radio. (Refer to dependencies detailed in the screen description above.) Enter
the Trunking Pager ID. This value represents the Trunking Pager ID of
the radio unit which serves as VRM100 master pager unit in the
VRM100 network. This pager unit may Call Alert the radio to activate
its data mode in order to communicate with the master VRM100.
Valid IDs range between 1 and 65534. The Pager ID is used for the
radio’s Private Conversation Call ID (7 + ID#), interconnect land-to-
portable unit calls (7 + ID#) and interconnect land-to-portable
Talkgroup calls (7 + ID#).
VRM100 Talkgroup This field will be visible only for Type II models and only if VRM100
operation has been enabled for the radio. (Refer to dependencies detailed in
the screen description above.) The value in this field represents a
Talkgroup dedicated to VRM100 data operation only. Enter the
Talkgroup IDs (three-digit) for this personality in Hexadecimal.
The default is 001.
VRM100 Size Code This field will be visible only for Type IIi models and only if VRM100
operation has been enabled for the radio. (Refer to dependencies detailed in
the screen description above.). Use the UP/DOWN arrow keys to choose
the Size Code for this personality. The Size Code determines the
maximum number of fleets, subfleets and individual IDs allowed.
Valid codes are: A, B, C, D, E, F, G, H, I, J, K, M, O and Q.
Size Code Prefix Fleet Subfleet
Individual
ID
A 0 - 7 00 - 7F A - C 000 - 00F
B 0 - 7 00 - 0F A - G 000 - 03F
C 0 - 7 00 - 07 A - G 000 - 07F
D 0 - 7 00 - 00 A - O 000 - 1FF
E 0 - 7 00 - 3F A - C 000 - 01F
F 0 - 7 00 - 1F A - G 000 - 01F
G 0 - 7 00 - 1F A - C 000 - 03F
H 0 - 7 00 - 0F A - C 000 - 07F
I 0 - 7 00 - 07 A - C 000 - 0FF
J 0 - 7 00 - 03 A - G 000 - 0FF
K 0 - 7 00 - 01 A - C 000 - 0FF
M 0, 2, 4, 6 00 - 00 A - C 000 - 3FF
O 0 - 4 00 - 00 A - C 000 - 7FF
Q 0 - 0 00 - 00 A - C 000 - FFF