235
Tx Base Time (sec) Use the UP/DOWN arrow keys to select the desired MDC Tx Base Time.
The value may also be entered directly. The MDC Tx Base Time is a
value used to calculate the period that a radio will key-up after
receiving an MDC Remote Monitor/Radio Trace command. This Tx
Base Time is multiplied by a second value that is sent from the
dispatch console and transmitted to the radio via an MDC Remote
Monitor/Radio Trace command. The range is from 10 to 120 seconds
in 10 second increments.
Rx Base Time (sec) Use the UP/DOWN arrow keys to select the desired MDC Tx Base Time.
The value may also be entered directly. The MDC Rx Base Time is a
value used to calculate the period that a radio will 'listen' after keying-
up while it is in the Remote Monitor mode. This Rx Base Time is
multiplied by a second value that is sent from the dispatch console
and transmitted to the radio via a Remote Monitor/Radio Trace
command. The range is from 10 to 120 seconds in 10 second
increments.