3 Press Abort Call.
4 Repeat step 1 through step 3 for Phone and Emergency calls.
4.11
Digital Duplex Test (Tx) using IFR 3901/IFR 3902/IFR 3920
Procedure:
1 On the radio, press MenuContactContact 1Send.
The following results are displayed on the Tx Measurements window.
Burst Power Required Results: 28.0–32.0 dBm (Class 4) or 30.5–34.5 dBm
(Class 3L)
Power Profile: Passed
Burst Timing: ± 0.25 Symbols
Vector Error: Max 10% RMS, Max 30% Peak, Max 5% residual
Frequency Error: ± 100 Hz
2 Press Call MobileGroup CallTALKBACK.
3 Speak into the microphone of the handset.
You hear your speech (after a short delay) from the internal earpiece of the handset.
4 If you need more details, select
at the Rx Measurement Window.
For... Then...
Power Analyzer Graph
a Select PowerProfile Full.
b To view the detail of Profile Full, select
and press
Select.
c To minimize the window, press Select.
d To view the rest of the power analyzer graphs, select
any item under Power drop-down list.
Vector Analyzer Diagram
a Select Mod AccuracyVector Error.
b To view the detail of Vector Error, select
, and press
Select.
c To minimize the window, press Select.
d To view the rest of the vector analyzer graphs, select
any item under Mod Accuracy drop-down list.
5 Press End on the handset.
4.12
Digital Duplex Test (Tx) using IFR 2968
Procedure:
1 On the radio, press MenuContactContact 1Send.
The following results are displayed on IFR Manual Test Screen.
Burst Power Required Results: 28.0–32.0 dBm (Class 4) or 30.5–34.5 dBm
(Class 3L)