AirWorks AWK-1137C Web Console Configuration
3-27
3. Click Upload Certificate File to import the certificate file. If the import succeeds, you can see the
information uploaded in Current Certificate. If it fails, you may need to return to step 1 to set the
password correctly and then import the certificate file again.
NOTE
The
WLAN certificate will remain after the AWK-1137C reboots. Even though it is expired
, it can still be seen on
the
Current Certificate.
Serial Port Settings
The AWK-1137C is provided with a serial port for connecting serial devices to the WLAN network. The AWK
support various useful serial operation modes to make connecting to your serial devices much simpler.
Operation Modes
The Operation Modes page for the serial port is where you can configure the serial port operation mode and
related settings.
Application
This field specifies the application of this serial port. Depending on the application, the different operation
modes and their settings will be displayed.
Setting Description Factory Default
Disable This serial port will be disabled. Device Control
Device Control This serial port will be used to control a device using legacy
software installed on a Windows, Linux, or UNIX system.
Drivers will need to be installed that will allow your software to
communicate with the device as if it were physically
attached to
a local COM or TTY port. You may select between Real
COM and
RFC2217 operation modes.
Socket This serial port will be used for a TCP or UDP socket-based
application. You may select between TCP Client, TCP Server,
and UDP operation modes.
NOTE
We recommend disabling the port if no serial devices are connected to the AWK.