AirWorks AWK-1137C Web Console Configuration
Configuration-related events Event is triggered when…
Configuration Changed A configuration item has been changed.
Configuration file import via Web Console
The configuration file is imported to the AWK-1137C.
Console authentication failure An incorrect password is entered.
Firmware upgraded The AWK-1137C’s firmware is updated.
Configuration reset to default The configuration is reset to factory default.
Power events Event is triggered when…
Power transition (On -> Off) The AWK-1137C is powered down
Power transition (Off -> On) The AWK-1137C is powered.
Syslog
This function provides the event logs for the Syslog server. The function supports up to three configurable
Syslog servers and Syslog server UDP port numbers. When an event occurs, the event will be sent as a Syslog
UDP packet to the specified Syslog servers.
Syslog Event Types
Detailed information for the grouped events is shown in the following table. Check the box for Enable logging
to enable the grouped events. All default values are enabled (checked). Details for each event group can be
found in the “System Log Event Types” section.
Syslog Server Settings
You can configure the parameters for your Syslog servers in this page.
Syslog server 1/ 2/ 3
Setting Description Factory Default
IP address Enter the IP address of the 1st/ 2nd/ 3rd Syslog Server None
Syslog port
Setting Description Factory Default
Port destination
(1 to 65535)
Enter the UDP port of the corresponding Syslog server 514