AirWorks AWK-1137C Web Console Configuration
carriage return character could be used as a delimiter in orde
to transmit each sentence or paragraph in a separate packet.
Data will be packed according to Delimiter process.
Delimiters must be incorporated into the data stream at the
software or device level. The Delimiter value can be set ranging
from 00 to FF.
Delimiter 1 is enabled, Packet length must be set to 0.
Delimiter Process
This field specifies how data is packed when delimiter characters are received. This field has no effect if
Delimiter 1 is not enabled.
Setting Description Factory Default
Do Nothing Data accumulated in the serial port’s buffer will be packed,
including delimiters.
Do Nothing
Delimiter + 1 One additional character must be received before the data in
the serial port’s buffer is packed.
Delimiter + 2
Two additional characters must be received before the data in
the serial port’s buffer is packed.
Strip Delimiter
Data accumulated in the serial port’s buffer will be packed, but
the delimiter character(s) will be stripped from the data.
Force Transmit
This field controls data packing by the amount of time that elapses between bits of data. When using this field,
make sure that Inactivity time is disabled or set to a larger value. Otherwise the connection may be closed
before the data in the buffer can be transmitted.
Setting Description Factory Default
0 to 65535 0: If serial data is received, setting this value to 0 means no
data will be buffered and all data will be transmitted
immediately as received.
1 to 65535: If serial data is not received for the specified
amount of time, the data that is currently in the buffer will be
packed for network transmission. The optimal force transmit
time depends on your application, but it must be at least larger
than one character interval within the specified baudrate. For
example, assume that the serial port is set to 1200 bps, 8 data
bits, 1 stop bit, and no parity. In this case, the total number of
bits needed to send a character is 10 bits, and the time required
to transfer one char
acter is 8.3 ms, so the force transmit time
should be greater than 8.3 ms.
0 ms