Technical Specifications/CertificationsMSA
ALTAIR 5X/ALTAIR 5X IR
GB
71
5.6 Certification
See device label for the approvals that apply to your specific device.
USA and Canada
Other Countries
USA
USA / NRTL
[Intrinsic Safe-
ty, Non-Min-
ing]
UL913 for Class I, Div. 1, Groups A, B, C and D, Class II, Div. 1,
-40°C to +50°C, T4
Canada
Canada / CSA
[Intrinsic Safe-
ty, Combusti-
ble
Performance,
Non-Mining]
CSA C22.2 No. 157 for Class I, Div. 1, Groups A, B, C and D
CSA C22.2 No. 152 M1984 Combustible Performance
Tamb = -40°C to +50°C, T4 for Intrinsic Safety
Tamb = -20°C to +50°C, T4 for Combustible Performance
Australia
[Intrinsic Safe-
ty, Industrial
and Mining -
TestSafe]
ALTAIR5X / ALTAIR5XiR
Ex ia s Zone 0 I IP65
Ex ia s Zone 0 IIC T4 IP65, Tamb = -40°C to +50°C
IEC60079-0, IEC60079-1, IEC60079-11, AS-1826