- All device readings and information must be interpreted by someone trained
and qualified in interpreting device readings in relation to the specific environ-
ment, industrial practice and exposure limitations.
- Use of the Galaxy® Automated Test System is an alternate MSHA-approved
method for calibrating MSHA-approved ALTAIR 5X devices.
- Use only calibration gas that is 2.5 % Methane with an accuracy of +5 % when
calibrating MSHA-approved ALTAIR 5X devices.
- The maximum acceptable user-set [password protected] Galaxy Test System
tolerance on Bump Limits must be set to 10 % or less when calibrating MSHA-
approved ALTAIR 5X devices.
- For 30 CFR Part 75 determinations, the maximum acceptable userset [pass-
word protected] Galaxy Test System tolerance on Bump Limits must only be set
to such that 19.5 % oxygen can be detected with an accuracy of +0.5 % when
calibrating MSHA-approved ALTAIR 5X devices.
Observe proper battery maintenance
Use only battery chargers made available by MSA for use with this device; other
chargers may damage the battery pack and the device. Dispose of in accordance
with local health and safety regulations.
Be aware of environmental conditions
A number of environmental factors may affect the sensor readings, including
changes in pressure, humidity and temperature.
Pressure and humidity changes also affect the amount of oxygen actually present
in the atmosphere.
Be aware of the procedures for handling electrostatically sensitive
electronics
The device contains electrostatically sensitive components. Do not open or repair
the device without using appropriate electrostatic discharge [ESD] protection. The
warranty does not cover damage caused by electrostatic discharges.
Be aware of the product regulations
Follow all relevant national regulations applicable in the country of use.
Be aware of the warranty regulations
The warranties made by Mine Safety Appliances Company with respect to the prod-
uct are voided if the product is not used and maintained in accordance with the in-