9
Alarm messages
106
30303187-02-EN
TRAIL-Control
Text of alarm message
Meaning
Defective drawbar angle sensor.
The analog input voltage is outside of the valid range.
Valid range: 0.5 V to 4.5 V
1. Replace the angle sensor.
Defective slope sensor.
The analog input voltage is outside of the valid range. Valid range: 0.5 V to 4.5 V
1. Replace the slope sensor.
Defective gyroscope.
The analog input voltage is outside of the valid range. Valid range: 0.5 V to 4.5 V
1. Replace the gyroscope.
Calibration must be performed
No valid value for the drawbar middle position.
1. Calibrate TRAIL-Control.
Check parameters
Values in the configuration outside of the valid range:
With drawbar steering:
Drawbar length: 80cm - 300cm
Frame length: 100cm - 500cm
With stub axle steering:
Drawbar length: 200cm - 800cm
1. Enter the correct values in the password-protected area.
The slope sensor is not correctly
mounted
Valid voltage range during calibration: 1.5V to 3.5V
The drawbar angle sensor is not
correctly installed.
Valid voltage range during calibration: 1.5V to 3.5V
The gyroscope is not correctly
installed.
Valid voltage range during calibration: 1.5V to 3.5V
The drawbar angle sensor is reversed.
The wrong direction of rotation was detected during calibration of the limit stops.